{"datasetId":7,"datasetName":"CapacityPerMunicipality","title":"Capacity per Municipality","description":"Capacity and number of production units per municipality and type.","organizationName":"tso-electricity","updateFrequency":"P1M","comment":"The dataset is updated during the first two weeks of the following month.\n\n**Please note:** the capacities are calculated at midnight on the first day of the month.\n\nA version, where thermal power plants are divided into main fuels, is under development.\n\n---\n**API Request Frequency**\u202F\\\nTo get the most up-to-date data, calling the API with a dynamic timestamp such as [start=now-P3M](https://api.energidataservice.dk/dataset/CapacityPerMunicipality?start=now-P3M) is a good approach. Making one request daily is sufficient to ensure getting the latest data.","caution":"","filterColumn":"Month","author":"Energinet","resolution":"1 month (P1M)","columns":[{"dbColumn":"Month","dataType":"date","sortOrder":1,"primaryKeyIndex":1,"displayName":"Month","unit":"Months","description":"Year and month based on local Danish time.","comment":"In **preview (in the GUI)** year and month is shown as YYYY-MM e.g. 2017-07. Please note that there is no time zone indicator, showing that this is local (Danish) time.\n\nIn **download (CSV and XLSX)** the datetime is exported as YYYY-MM-DD hh:mm:ss e.g. 2017-07-01 00:00:00. Excel will recognize it as date-time. The user must remember that this is local (Danish) time.\n\nIn **download (JSON and API)** the datetime is exported as YYYY-MM-DDThh:mm:ss e.g. 2017-07-01T00:00:00.","example":"2017-06","columnSize":7.0},{"dbColumn":"MunicipalityNo","dataType":"string","sortOrder":3,"primaryKeyIndex":2,"displayName":"Municipality number","unit":"Coded","description":"Each of the 98 Danish municipalities has a unique number, ranging from 101 Copenhagen to 860 Hjørring.","comment":"A list with the unique numbers can be found here: https://info.skat.dk/data.aspx?oid=2276646\r\nNumber from 101 - 400 is DK2\r\nNumbers from 410 is DK1","example":"101","columnSize":3.0},{"dbColumn":"CapacityGe100MW","dataType":"number","sortOrder":4,"displayName":"Capacity Power Plants greater than or equal to 100 MW","unit":"MW","description":"Total amount of capacity calculated at the beginning of a month from power plants greater than or equal to 100 MW. ","comment":"**Please note:** The capacity is calculated at midnight on the first day of the month.","example":"234,55","columnSize":9.2,"validationRules":">0"},{"dbColumn":"CapacityLt100MW","dataType":"number","sortOrder":5,"displayName":"Capacity Power Plants under 100 MW","unit":"MW","description":"Total amount of capacity calculated at the beginning of a month from powerplants under 100 MW. ","comment":"**Please note:** The capacity is calculated at midnight on the first day of the month.","example":"234,55","columnSize":9.2,"validationRules":">0"},{"dbColumn":"OffshoreWindCapacity","dataType":"number","sortOrder":6,"displayName":"Capacity Offshore Wind","unit":"MW","description":"Installed capacity of offshore wind generators at the beginning of a month.","comment":"**Please note:** The capacity is calculated at midnight on the first day of the month.","example":"234,55","columnSize":9.2,"validationRules":">0"},{"dbColumn":"OnshoreWindCapacity","dataType":"number","sortOrder":7,"displayName":"Capacity Onshore Wind","unit":"MW","description":"Installed capacity of onshore wind generators at the beginning of a month.","comment":"**Please note:** The capacity is calculated at midnight on the first day of the month.","example":"5,43","columnSize":9.2,"validationRules":">0"},{"dbColumn":"SolarPowerCapacity","dataType":"number","sortOrder":8,"displayName":"Capacity Solar Power","unit":"MW","description":"Installed capacity of solar power panels at the beginning of a month.","comment":"**Please note:** The capacity is calculated at midnight on the first day of the month.","example":"234,55","columnSize":9.2,"validationRules":">0"},{"dbColumn":"NumberGenerationUnitsGe100MW","dataType":"integer","sortOrder":9,"displayName":"Number of Thermal Power Plants greater than or equal to 100 MW","unit":"Number","description":"The total number of thermal Power plants  at the end of a month, greater than or equal to 100 MW. The number refers to market measuring points, not the number of generator.","comment":"","example":"3","columnSize":6.0,"validationRules":">=0"},{"dbColumn":"NumberGenerationUnitsLt100MW","dataType":"integer","sortOrder":10,"displayName":"Number of Thermal Power Plants under 100 MW","unit":"Number","description":"The total number of thermal Power plants under 100 MW at the end of a month. The number refers to market measuring points, not the number of generator.","comment":"","example":"3","columnSize":6.0,"validationRules":">=0"},{"dbColumn":"NumberOffshoreWindGenerators","dataType":"integer","sortOrder":11,"displayName":"Number of Offshore Wind Generators","unit":"Number","description":"The total number of offshore wind generators at the end of a month.","comment":"","example":"432","columnSize":6.0,"validationRules":">0"},{"dbColumn":"NumberOnshoreWindGenerators","dataType":"integer","sortOrder":12,"displayName":"Number of Onshore Wind Generators","unit":"Number","description":"The total number of onshore wind generators at the end of a month.","comment":"","example":"560","columnSize":6.0,"validationRules":">0"},{"dbColumn":"NumberSolarPanels","dataType":"integer","sortOrder":13,"displayName":"Number of Solar Panels","unit":"Number","description":"The total number of solar panels / installations at the end of a month.","comment":"","example":"5647","columnSize":6.0,"validationRules":">=0"}],"tags":["Active","Month","Monthly (P1M)","Municipality"],"dataFrom":"2016-01-01T01:00:00","dataTo":"2026-06-01T02:00:00","lastDataUpdate":"2026-07-21T08:09:50","lastMetadataUpdate":"2026-05-27T13:38:42","published":"2016-01-01T00:00:00","active":true,"operatingInformation":true,"filterColumnIsDate":true}